FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server  |   User: [n/a]

75446001: Mechanical complication of cardiac device, implant AND/OR graft (disorder)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jan 2002. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module Reference Sets
125311011 Mechanical complication of cardiac device, implant AND/OR graft en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core GB English: Preferred (foundation metadata concept)
816056013 Mechanical complication of cardiac device, implant AND/OR graft (disorder) en Fully specified name Active Only initial character case insensitive (core metadata concept) SNOMED CT core GB English: Preferred (foundation metadata concept)

5 descendants. Search Descendants:

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Mechanical complication of cardiac device, implant AND/OR graft Is a Complication of surgical procedure false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft Is a Mechanical complication of device true Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft Temporally follows Surgical procedure false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft Temporally follows Surgical procedure (procedure) false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft After Surgical procedure (procedure) false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft After Procedure false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft Associated with Surgical procedure (procedure) false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft Associated with Procedure false Inferred relationship Some
Mechanical complication of cardiac device, implant AND/OR graft Associated with Device true Inferred relationship Some 1

Inbound Relationships Type Active Source Characteristic Refinability Group
Disorder of implantable defibrillator Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical breakdown of cardiac device Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Disorder of cardiac pacemaker system Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Disorder of intra-aortic pulsation balloon Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical complication due to cardiac pacemaker electrode (disorder) Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Perforation of cardiac device Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical complication due to heart valve prosthesis Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical complication of intra-aortic balloon device Is a True Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Displacement of cardiac device Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Protrusion of cardiac device Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical obstruction of cardiac device Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical complication due to coronary bypass graft Is a True Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Mechanical complication of aortic graft Is a True Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Leakage of cardiac device Is a True Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some
Intra-aortic balloon rupture Is a False Mechanical complication of cardiac device, implant AND/OR graft Inferred relationship Some

This concept is not in any reference sets

Back to Start