Status: current, Sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2009. Module: SNOMED CT core
Descriptions:
Id | Description | Lang | Type | Status | Case? | Module | Reference Sets |
2818097019 | Percutaneous replacement of aortic valve using fluoroscopic guidance | en | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core | GB English: Preferred (foundation metadata concept) |
2818098012 | Percutaneous replacement of aortic valve using fluoroscopic guidance (procedure) | en | Fully specified name | Active | Entire term case insensitive (core metadata concept) | SNOMED CT core | GB English: Preferred (foundation metadata concept) |
2536231000052114 | perkutant byte av aortaklaff under röntgengenomlysning | sv | Synonym (core metadata concept) | Active | Entire term case insensitive (core metadata concept) | SNOMED CT Sweden NRC maintained module (core metadata concept) | Swedish [International Organization for Standardization 639-1 code sv] language reference set (foundation metadata concept): Preferred (foundation metadata concept) |
Outbound Relationships | Type | Target | Active | Characteristic | Refinability | Group | Values |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Procedure categorized by device involved (procedure) | false | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Fluoroscopic guidance | true | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Angiocardiography of left heart | false | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Cardiac fluoroscopy | true | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Procedure on heart valve | false | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Replacement procedure | false | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Method | Fluoroscopic imaging - action (qualifier value) | true | Inferred relationship | Some | 1 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Using device (attribute) | Aortic valve prosthesis | true | Inferred relationship | Some | 2 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Access | Percutaneous approach | true | Inferred relationship | Some | 2 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Method | Replacement - action | false | Inferred relationship | Some | 2 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Has intent | Guidance intent (qualifier value) | true | Inferred relationship | Some | 1 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Procedure site - Direct (attribute) | Aortic valve structure | true | Inferred relationship | Some | 1 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Procedure site - Direct (attribute) | Aortic valve structure | true | Inferred relationship | Some | 2 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Procedure site - Direct (attribute) | Aortic valve structure | false | Inferred relationship | Some | 3 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Access | Percutaneous approach | false | Inferred relationship | Some | 3 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Using device (attribute) | Aortic valve prosthesis | false | Inferred relationship | Some | 3 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Replacement of aortic valve | false | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Method | Surgical replacement - action | false | Inferred relationship | Some | 3 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Is a | Transcatheter aortic valve replacement (procedure) | true | Inferred relationship | Some | ||
Percutaneous replacement of aortic valve using fluoroscopic guidance | Method | Surgical replacement - action | true | Inferred relationship | Some | 2 | |
Percutaneous replacement of aortic valve using fluoroscopic guidance | Using access device (attribute) | Vascular catheter | true | Inferred relationship | Some | 2 |
Inbound Relationships | Type | Active | Source | Characteristic | Refinability | Group |
This concept is not in any reference sets