FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server  |   User: [n/a]

433844000: Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure)


Status: current, Not sufficiently defined by necessary conditions definition status (core metadata concept). Date: 31-Jul 2008. Module: SNOMED CT core

Descriptions:

Id Description Lang Type Status Case? Module Reference Sets
2745797015 Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) en Fully specified name Active Entire term case insensitive (core metadata concept) SNOMED CT core GB English: Preferred (foundation metadata concept)
2767439014 Insertion of cardiac biventricular implantable cardioverter defibrillator (ICD) using fluoroscopic guidance en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core GB English: Preferred (foundation metadata concept)
2767440011 Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance en Synonym (core metadata concept) Active Entire term case insensitive (core metadata concept) SNOMED CT core GB English: Acceptable (foundation metadata concept)
2773768011 Fluoroscopic guidance for insertion of cardiac biventricular ICD en Synonym (core metadata concept) Active Only initial character case insensitive (core metadata concept) SNOMED CT core GB English: Acceptable (foundation metadata concept)

0 descendants.

Expanded Value Set


Outbound Relationships Type Target Active Characteristic Refinability Group Values
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Insertion of cardiac defibrillator using fluoroscopic guidance (procedure) true Inferred relationship Some
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Is a Insertion of biventricular implantable cardioverter defibrillator (procedure) true Inferred relationship Some
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Automatic cardiac defibrillator false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Automatic cardiac defibrillator false Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Direct (attribute) Heart structure true Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Has intent Guidance intent (qualifier value) true Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Fluoroscopic imaging - action (qualifier value) true Inferred relationship Some 1
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Insertion - action (qualifier value) true Inferred relationship Some 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure true Inferred relationship Some 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Method Insertion - action (qualifier value) false Inferred relationship Some 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Implantable defibrillator false Inferred relationship Some 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Procedure site - Indirect (attribute) Heart structure false Inferred relationship Some 2
Insertion of cardiac biventricular implantable cardioverter defibrillator using fluoroscopic guidance (procedure) Direct device Implantable defibrillator true Inferred relationship Some 2

Inbound Relationships Type Active Source Characteristic Refinability Group

This concept is not in any reference sets

Back to Start